IP Protection Classes and Sealing: Clearly Separating the Display Stack and Housing
When Water and Dust Become a Project Problem at the Device Interface
In vehicles, machinery, and industrial equipment, a display must fit into an overall system that may be exposed to rain, dust, mud, or recurring cleaning cycles. Moisture and particles can become an issue at various points: on the visible surface, in joints, at connectors, at cable entries, or at the installation boundary. Therefore, the technical design depends not only on how the display stack is constructed. What matters most is which system configuration needs to be protected and which test specimen represents the intended application.
VIA optronics works with you to determine the role of the display stack within the overall protection chain. We separate the bonded optical section, the housing and sealing layers, and the electronics and interfaces. This creates a transparent foundation for further design and the coordination of the appropriate validation.
A Brief Explanation
Optical bonding can reduce the open space within the agreed-upon stack configuration, thereby supporting the bonded optical area. The outer protective boundary is formed by the housing, joints, seals, openings, connectors, and, if applicable, venting or pressure equalization concepts. An IP rating always applies to a specific test specimen, a specific configuration, and defined test conditions—not automatically to every display or every complete system.
The IP code and the test specimen go hand in hand
The IP code describes the protection of a defined enclosure against the ingress of solid foreign objects and water under specified test conditions. The first digit refers to solid foreign objects and access to hazardous parts; the second refers to water. An IP protection rating is therefore not an isolated property of a single component, but rather a statement about the tested system boundary.
A higher IP rating is not necessarily the more suitable solution for every application profile. The specific stresses and test conditions are decisive: rain, splashing water, dust, mud, temporary submersion, or scheduled cleaning all impose different requirements. For electrical equipment in road vehicles, ISO 20653 can also provide a project-specific framework in addition to IEC 60529[1][2]. The responsible project partners coordinate which standard and procedure to use for the respective configuration.
Decision within the Project
Technical Classification
Result of the Assessment
What exposure is to be expected?
For example, dust, rain, splashing water, submersion, or cleaning.
The actual operating and cleaning profile is defined.
Which part of the system defines the protection boundary?
Bonded stack, housing, joints, connections, cable entries, or electronics.
The relevant entry paths and areas of responsibility are defined.
To which version does the verification apply?
For a documented configuration with defined assembly and test conditions.
The specific test specimen and the agreed-upon test framework are specified.
Even a modified opening, installation, or pressure equalization solution can alter the relevant protection limit and thus the test specimen to be evaluated. That is why we incorporate design changes into the technical coordination at an early stage.
Three levels of protection in the display system
Display Stack
The display stack comprises the display, cover glass, and—if applicable—the touch panel, including the coordinated bonding assembly. Optical bonding connects the intended layers and can reduce the open optical gap within this defined assembly. This alters the geometry of the gap where particles can accumulate or moisture can be trapped. This contribution refers to the agreed-upon stack and does not automatically establish a protection rating for the entire device.
Housing and Sealing Level
The housing and sealing level protects the system as a whole. This includes frames, joints, seals, housing openings, and the interface for installation. A cover glass may be a structural part of this boundary, but it alone does not result in an IP rating for the entire device. Ventilation and pressure equalization concepts must also be evaluated separately, as they can affect the protective boundary and the relevant test specimen.
Electronics and Interface Level
The electronics and interface level includes, among other things, printed circuit boards, contacts, connectors, and cable entries. These areas require their own protection concept. A sealed optical gap does not replace either the sealing of a connector or the evaluation of the electronics within the complete test specimen. Salt, cleaning agents, and other chemical influences are taken into account as components of the application profile; no general statement regarding resistance can be derived from the display stack alone.
Optically bonded display assembly
Schematic protection boundaries of a display system with a bonded stack, housing seal, and interfaces.
Optical Bonding as a Contribution to the Protection Chain
When it comes to IP, the relevant contribution of optical bonding lies within the defined display stack. VIA optronics coordinates the material, layer structure, and intended use of the bonding process with you on a project-by-project basis. In doing so, we also consider the edge zone and the connection to the intended housing design, provided these aspects fall within the agreed-upon scope of the project.
The qualification of the complete device—including the housing, seals, connectors, and assembly—is coordinated within the defined scope of responsibility of the relevant project partners or a suitable testing laboratory. Which tests VIA conducts or oversees is determined on a project-by-project basis according to the agreed-upon scope of testing. Therefore, we do not derive a blanket protection rating for an HMI, a device, or a machine from a single display stack.
For the design, please provide
For joint technical coordination, please provide the application and cleaning profile, the expected exposure to water and dust, and any potential exposure to salt or chemicals. Also relevant are the housing and installation concept, connections, cable routing, and the intended display, cover glass, and touch configuration.
Four steps to the right IP test framework
1. Together, we define the application and cleaning profile, including the relevant water, dust, and environmental exposure.
2. We define the display stack, housing, seals, connectors, electronics, and ventilation and pressure equalization concepts as separate technical protection zones.
3. We document the specific configuration, including assembly, openings, and interfaces for the test specimen to be evaluated.
4. We coordinate the test conditions, scope of verification, and areas of responsibility among the relevant project partners for this implementation.
The statement applies to the defined test specimen and the specified test conditions—not automatically to every variant, assembly, or subsequent design change. This ensures that the technical design and responsibilities remain traceable throughout the entire scope of the project.
Frequently asked questions about IP protection ratings and water resistance
Does optical bonding provide an IP rating?
No, optical bonding supports the defined bonded area of the display stack. The IP protection rating, on the other hand, refers to a specific test specimen with a housing, seals, interfaces, and specified test conditions. We therefore coordinate the stack’s contribution and the certification for the complete system separately.
Last update on 2026-11-25 by mederer.
Does an IP certification remain valid after a design change?
That depends on the changed configuration. A different cover glass, a new gasket, an additional housing opening, a modified connector, a different assembly method, or a new pressure equalization solution can alter the protection boundary and the relevant test specimen. Together, we will determine whether the change falls within the scope of the existing agreement or requires a re-evaluation by the responsible project partners.
Discuss your application profile, the intended display stack, and the enclosure interfaces with VIA optronics. Together, we will develop a clear matrix of responsibilities and testing requirements for the stack, enclosure, and system. This will help you take the appropriate next step in your project—from defining technical scope to coordinating the relevant IP certification.